第10回
ACM センサを用いた空調ダクトの予防保全計画
著者:
福場 一司,Kazushi FUKUBA,藤 孝信,Takanobu ITO,島 明子,Akiko KOJIMA,丹治 和宏,Kazuhiro TANJI,佐藤 優樹,Yuki SATO
発刊日:
公開日:
キーワードタグ:
Air-conditioning duct is difficult to predict the date to occur of corrosion such as affect the function. Therefore, the current conservation method is mostly corrective maintenance. Therefore, was used the test pieces of six types and ACM-sensor in order to solve the corrosion speed from corrosion environment and relationship of corrosion quantity of test pieces. In addition, was used the duct molded articles various in order to check the corrosion degree of when processed the duct. As a result, we we...
英字タイトル:
Preventive maintenance plan of the air-conditioning duct using the ACM-sensor
第6回
東北電力の原子力発電所における配管肉厚管理の概要
著者:
秋葉 真司,Shinji AKIBA,丹治 和宏,Kazuhiro TANJI,河上 晃,Akira KAWAKAMI
発刊日:
公開日:
キーワードタグ:
Pipe wall thinning is an aging process that has a significant effect on the safety and safe operation of power plants and its appropriate management is an issue common to a ll electric power companies. Tohoku Electric Power Co., Inc. has been putting an emphasis on pipe wall thickness management since 2006, when a through-hole possibly due to droplet-impact erosion was found in the vent piping of high-pressure feedwater heater No.2 at Onagawa Nuclear Power Station unit 2. Following this incident, extensive...
英字タイトル:
Overview of Pipe Wall Thickness Management at Tohoku Electric Power
第16回
東通原子力発電所1号機における敷地内断層の補足調査について
著者:
丹治 和宏,小野寺 正典,(東北電力)
発刊日:
公開日:
キーワードタグ:
Since June 2014, the Higashidori Nuclear Power Station had been taking the assessment of the on-site fault in the conformity assessment of the new regulatory standard. After that, although the assessment of the fault located directly under key facilities ended in 2018, We are taking an assessment of active fault examination considered as an epicenter at present. This document is a summary of the supplementary survey including geology survey such as reflection survey and boring exploration for active fault a...
英字タイトル:
Supplemental investigation on faults in site of Higashidori Nuclear Power Plant Unit 1
第11回
電磁超音波共鳴法を用いた配管減肉検査における底面形状の影響
著者:
浦山 良一,Ryoichi URAYAMA,ジョン マンチョル,Jeong Man Chul,原 翔一郎,Syoichiro HARA,高木 敏行,Toshiyuki TAKAGI,内一 哲哉,Tetsuya UCHIMOTO,丹治 和宏,Kazuhiro TANJI
発刊日:
公開日:
キーワードタグ:
Electromagnetic acoustic transducer (EMAT) provides non-contacting measurements and is often applied to monitoring in high temperature environment. Electromagnetic acoustic resonance method (EMAR) is transmits an ultrasonic burst wave, and the driving frequency of bust wave is swept. Then signal amplitude of each frequency is computed by the superheterodyne processing at the interval. Pulse-EMAR method is transmits an ultrasonic pulse wave propagating, but the pulse wave is not swept. Then echo waves recei...
英字タイトル:
Influence of bottom shape in the pipe wall thinning inspection using an electromagnetic acoustic resonance method